Exterior Wall Cladding
Full-envelope cladding for buildings exposed to sun, rain, and seasonal temperature swings. The core FlowVeins application.
Ask about this applicationAPPLICATIONS
FlowVeins is engineered for the building envelope — the surfaces that take the weather and carry the design intent. Below are the six application areas where it performs, each with its own set of specification requirements.
APPLICATION TYPES
Six application areas, each with different demands on the cladding. Pick the one closest to your project — or ask us to specify directly for it.
Full-envelope cladding for buildings exposed to sun, rain, and seasonal temperature swings. The core FlowVeins application.
Ask about this applicationSemi-exposed and open-air surfaces — pool surrounds, terraces, garden walls — where moisture and UV load is constant.
Ask about this applicationHorizontal and vertical siding systems in the North American sense — board-by-board installation over a framed wall.
Ask about this applicationVentilated rainscreen assemblies where drainage and airflow behind the panel decide how long the wall lasts.
Ask about this applicationArchitectural facades where the cladding is the design statement — texture, shadow line, and proportion in one system.
Ask about this applicationRetail, hospitality, and office exteriors where fire classification, maintenance access, and supply scale all matter.
Ask about this applicationWHY IT HOLDS UP OUTDOORS
Whichever application you are specifying for, the same things decide whether a cladding lasts. These are the four we test — and the numbers we can show.
3,000 h accelerated aging, ΔE*ab 2.7, grey scale rating 4 (ASTM G154).
24 h soak: 1.8% water absorption, 0% thickness swelling (ASTM D1037).
28.3 MPa flexural strength after −29°C freeze-thaw cycling (ASTM D7031).
EN 13501-1 classification B-s3, d0 — documented for commercial specification.
Data from SGS reports on MexyTech ASA-surface exterior boards (SDHL2407013318HI / SDHL2408014917HI / SDHL250601030601HI / SDHL250200203201HI). Full reports on request.
MATCHING PROFILE TO PROJECT
Two profiles cover the range — the difference is face width, section depth, and how much wall you need to cover per panel.

FV01
Flat design — 178 × 15 mm
Best where linear detail and tighter rhythm matter.

FV02
Siding design — 223 × 25 mm
Best for larger surfaces and higher load exposure.
COLOR GUIDES
Color behaves differently on a sunlit facade than it does on a shaded feature wall. Each guide covers one tone in depth.






SEE IT BUILT
Specification only goes so far. These are the kinds of projects FlowVeins has been installed on — and the conditions it was specified for.